Fluke Calibration 9132 - Certify IR pyrometers (–30 °C to 500 °C)

  • Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
  • Large 57 mm (2.25 in) blackbody target
  • RTD reference well for high precision
  • Small, compact design
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1658210
€6 244,80 €5 204 bez DPH
Fluke Calibration 9132 - Certify IR pyrometers (–30 °C to 500 °C)
Fluke 9132 - prenosné čierne teleso (–30 °C až 500 °C)
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30°C to 500°C. 

These units feature a temperature controlled measurement surface with a diameter of 2.25" (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30°C to 500°C and a well is located directly behind the blackbody surface for contact calibration.   9132 with IR

9132 

For IR calibrations above normal ambient, the 9132 provides a stable measurement surface up to 500°C (932°F). Short heating and cooling times mean you won’t have to wait long to get your work done.

9133 

If you’re calibrating IR guns at cold temperatures, you’ll love our new 9133. With solid-state cooling technology, this new IR calibrator reaches –30°C (22°F) in normal ambient conditions. With a conveniently located dry gas fitting on the front bezel, ice build up on the target can be avoided. At the upper end of its range, the 9133 provides stable temperatures to 160°C (320°F). 

With heating and cooling times of about 15 minutes from ambient to either extreme, the 9133 gets you to temperature quickly and performs when it gets there.

Specifications 9133  9132 

Temperature Range 

–30 °C to 150 °C at 23 °C ambient
(–22 °F to 302 °F at 73 °F ambient) 

50 °C to 500 °C
(122°F to 932°F) 

Accuracy 
(does not include emissivity)

±0.4 °C (±0.72 °F) 

±0.5 °C at 100 °C
(±0.9°F at 212°F) 
±0.8 °C at 500 °C
(±1.4 °F at 932 °F) 

Stability 

±0.1 °C (±0.18 °F) 

±0.1°C at 100°C
(±0.18°F at 212°F) 
±0.3°C at 500°C
(±0.54°F at 932°F) 

Target Size 

57 mm (2.25 in) 

Target Emissivity 

0.95 (±0.02 from 8 to 14 mm) 

Resolution 

0.1 ° 

Heating Time 

15 minutes (25 °C to 150 °C) 

30 minutes (50 °C to 500 °C) 

Cooling Time 

15 minutes (25 °C to –20 °C) 

30 minutes (500 °C to 100 °C) 

Computer Interface 

RS-232 I/O included with 9930 Interface-it software 

Power 

115 VAC (±10 %), 1.5 A, or
230 VAC (±10 %), 1.0 A, switchable, 50/60 Hz, 200 W 

115 VAC (±10 %), 3 A or
230 VAC (±10 %), 1.5 A, switchable, 50/60 Hz, 340 W 

Size (HxWxD) 

152 x 286 x 267 mm
(6 x 11.25 x 10.5 in) 

102 x 152 x 178 mm
(4 x 6  x 7 in ) 

Weight 

4.6 kg (10 lb) 

1.8 kg (4 lb) 

NIST-Traceable Contact Calibration 

Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C 

Data at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C 


Ordering Information

9132 

Portable IR Calibrator, 500 °C 

9308 

Rugged Carrying Case, 9132 

   

9133 

Portable IR Calibrator, –30 °C 

9302 

Rugged Carrying Case, 9133 

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: