Fluke Calibration 9101 - Zero-Point Dry-Well

  • Jednoduchá rekalibrácia zabezpečuje dlhodobú spoľahlivosť
  • Nová technológia chladenia „Solid-state"
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1657892
€5 019,60 €4 183 bez DPH
Fluke Calibration 9101 - Zero-Point Dry-Well
Fluke 9101 - suchá piecka pre 0°C
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Have you been thinking about buying a zero-point dry-well? Forget those ugly-looking units the competition makes. You can get a great looking and great performing zero-point dry-well from Hart Scientific. 

The Hart 9101 has three test wells for inserting more than one probe at a time. All three wells are stable to ±0.005 °C. One well accommodates changeable inserts for varying probe diameters. 

The Model 9101 takes advantage of the latest solid-state cooling technology rather than relying on older, less reliable sealed-water-cell devices. This eliminates the possibility that the sealed water cell will freeze and burst while transporting the unit to field locations. And our solid-state cooler is run by an adjustable electronic controller that can be recalibrated in your lab for convenient recertification. Simply place a certified standards thermometer in one of the wells and, if needed, tweak the 9101 controller until the standards thermometer reaches equilibrium at 0 °C. 

Since the unit is completely self-contained and doesn’t require any user settings, you can run it on demand for instant access to an accurate, traceable zero point. Set it up with the reference junction of a thermocouple for high-accuracy thermocouple measurements. 

Less costly than refrigerated baths, more accurate and less problematic than ice baths, and more durable and better looking than competitive units using sealed-water cells, the Hart 9101 Zero-Point Dry-Well is a great choice for any calibration lab!

Specifications 

Temperature Range 

0 °C (32 °F) 

Stability 

±0.005 °C 

Total Instrument Error 

±0.02 °C, typical; ±0.05 °C max. (18–25 °C ambient) 

Stabilization Time 

Approx. 30 minutes
(the ready lamp indicates stable control at 0 °C) 

Temperature Coefficient 

±0.005 °C/ °C amb. 

Size (HxWxD) 

311 x 216 x 150 mm
(12.25 x 8.5 x 6 in) 

Power 

115 VAC (±10 %), 1 A or 230 VAC (±10 %), 0.5 A, specify, 50/60 Hz, 125 W 

Well Dimensions 

2 wells 6.4 mm dia. x 152 mm  D (0.25  x 6 in), 1 well 7 mm dia. x 152 mm D (0.28 x 6 in). Includes one set of telescoping inserts to provide various smaller diameters 

Weight 

5.4 kg (12 lb.) 

NIST-Traceable Calibration 

Data at 0 °C 


Ordering Information 

9101 

Zero-Point Dry-Well (includes one set of telescoping inserts to provide various smaller diameters) 

2130 

Spare Well-Sizing Tube Set 

9325 

Rugged Carrying Case 

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: