Fluke Calibration 5907 - Aluminum Cell, Traditional Quartz Glass

  • Best cell uncertainties commercially available
  • Every ITS-90 fixed point available from mercury to copper 
  • Plateaus last days (gallium for weeks and TPW for months)
  • Manufactured and tested by Hart’s primary standards scientists
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1656557
€19 648,80 €16 374 bez DPH
Fluke Calibration 5907 - Aluminum Cell, Traditional Quartz Glass
Fluke 5907 - ITS-90 trojný bod hliníku
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Hart scientists have designed and tested ITS-90 fixed-point cells for many years. Not only do we manufacture all the major fixed points, our metrologists have written extensively on the theory and use of cells and have created new designs covering a range of applications no other company can match. 

Our testing of fixed-point cells is also unmatched. The scope of our accreditation includes the testing of ITS-90 fixed-point cells. Each cell may be purchased with this intercomparison option, which includes comparing the equilibrium value of your cell against that of a reference Hart cell. 

Traditional freeze-point cells 

If you want true primary temperature standards capability, you want metal freeze-point cells that are very close to the theoretical freezing temperature and provide plateaus that are both stable and long lasting. 

Hart’s metal freeze-point cells are the culmination of more than 20 years of primary standards experience. No other company has as much experience in the development of metal fixed-point cells as Hart. That’s why you’ll find Hart cells in many national metrology institutes around the world. 

Each Hart cell is carefully constructed in our ultra-clean, state-of-the-art lab, using high-density, high-purity graphite crucibles containing metal samples with purity of at least 99.9999 % (six 9s) and, in many cases, 99.99999 % (seven 9s). The crucible is enclosed within a sealed quartz glass envelope that is evacuated and back-filled with high-purity argon gas.  A special sealing technique is used to seal the cell at the freezing point. We measure and record for you the precise pressure of the argon gas to ensure the most accurate corrections for pressure. 

Once manufactured, all Hart cells are tested and supplied with an assay of metal-sample purity. Every traditional size ITS-90 cell further undergoes more rigorous testing in our primary standards lab where we realize melt-freeze curves and perform a detailed “slope analysis” to confirm cell purity. If you want more data, we’ll give you an optional intercomparison with our own reference cells. 

Gallium cells 

Gallium cells are a great reference for validation of instruments subject to drift (like SPRTs), and they’re important for calibrating sensors used near room or body temperatures, in environmental monitoring, and in life sciences applications. 

Hart’s 5943 Gallium Cell is sealed in a stainless steel envelope. High purity gallium (99.99999 %) is enclosed in a plastic and metal shell. The stainless steel container is then filled with pure argon gas at one standard atmosphere at the melting-point temperature. 

Gallium expands by 3.1 % when it freezes requiring the cell to have flexible walls. Unlike some manufacturers’ cells, which are made from PTFE enclosure materials, our cells don’t need pumping and refilling because they’re not gas permeable. In fact, we guarantee our cells will maintain their uncertainty of < 0.1 mK for at least five years. Realization and maintenance of the cell is automated with our 9230 Maintenance Apparatus (see page 31). This apparatus will provide melting plateaus up to eight days and a convenient control to automatically achieve a new melt plateau each week with an investment of just five minutes. Never has the maintenance of a world-class gallium cell been easier. 

Water cells 

While simple ice baths are often used as a calibration point at 0 °C, their limitations include gradients, purity problems, repeatability issues, and variances in construction and measurement techniques. Triple point of water cells not only solve these problems; they represent the most used temperature on the ITS-90, and they’re inexpensive to own and use. 

Hart makes three traditional-size TPW cells (see page 14) that have been repeatedly proven in national labs to surpass their published uncertainty specification of ±0.0001 °C. Ice mantles may be formed using dry ice, LN2, or immersion freezers and can last for up to two months when maintained in our 7012 or 7312 baths. 

Open metal cells 

Made from the same materials and with the same manufacturing techniques as their sealed counterparts, Hart’s new series of “open” metal fixed-point cells include a high quality valve for connecting to a precision pressure-handling system within your lab. Using such a system, the cell can be evacuated, charged, and purged several times with a pure inert gas, then charged again to a regulated pressure level while measurements are made with the cell. 

 
Once assembled and tested, each Hart ITS-90 open cell further undergoes more rigorous testing in our lab, unlike cells from some manufacturers who provide their open cells as a kit of parts, without any test data. 

Because open cells allow users to measure the pressure within the cell, uncertainties due to pressure corrections may be minimized. Use of open cells is now being suggested by the CCT, and open cells can be used for demanding temperature-versus-pressure applications, as well as precision SPRT calibrations. 

The height of these cells has been extended to allow easy access to the gas valve while the cells are in use. Pure quartz-wool insulation and four high-purity graphite discs prevent heat loss from the metal sample to the pressure regulation system while optimizing vertical temperature gradients within the cell. Each cell has an outside diameter of 50 mm (2 inches) and a height of 600 mm (23.5 inches)—(silver and copper cells are 700 mm [27.6 inches] tall). 

When it comes to primary temperature standards, Hart supplies more equipment than all of our competitors combined. If your goal is to reduce uncertainty, start by buying from the company that supports its products better than any other metrology company in the world. Why trust your primary standards to any other company? 

See how Hart"s metal fixed-point cells tested at NIST.

Specifications



Model


Fixed Point



Style


Assigned
Value
( °C)


Outside
Diameter


Inside
Diameter

Total Outside
Cell Height



Depth‡

Cell Uncertainty (mK, k=2)


Certification (mK, k=2)†

5900

Mercury

Stainless Steel

–38.8344

31 mm

8.2 mm

470 mm

200 mm

0.2

0.25

5904

Indium

Traditional Quartz Glass

156.5985

48 mm

8 mm

285 mm

195 mm

0.7

0.7

5905

Tin

Traditional Quartz Glass

231.928

48 mm

8 mm

285 mm

195 mm

0.5

0.8

5906

Zinc

Traditional Quartz Glass

419.527

48 mm

8 mm

285 mm

195 mm

0.9

1.0

5907

Aluminum

Traditional Quartz Glass

660.323

48 mm

8 mm

285 mm

195 mm

1.3

1.8

5908

Silver

Traditional Quartz Glass

961.78

48 mm

8 mm

285 mm

195 mm

2.4

4.5

5909

Copper

Traditional Quartz Glass

1084.62

48 mm

8 mm

285 mm

195 mm

10.1

12.0

5924

Indium

Open Quartz Glass

156.5985

50 mm

8 mm

596 mm

195 mm

0.7

0.7

5925

Tin

Open Quartz Glass

231.928

50 mm

8 mm

596 mm

195 mm

0.5

0.8

5926

Zinc

Open Quartz Glass

419.527

50 mm

8 mm

596 mm

195 mm

0.9

1.0

5927A-L

Aluminum

Open Quartz Glass (long)

660.323

50 mm

8 mm

696 mm

195 mm

1.3

1.8

5927A-S

Aluminum

Open Quartz Glass (short)

660.323

50 mm

8 mm

596 mm

195 mm

1.3

1.8

5928

Silver

Open Quartz Glass

961.78

50 mm

8 mm

696 mm

195 mm

2.4

4.5

5929

Copper

Open Quartz Glass

1084.62

50 mm

8 mm

696 mm

195 mm

10

12.0

5943

Gallium

Stainless Steel

29.7646

38.1 mm

8.2 mm

250 mm

168 mm

0.1

0.1

†Certifications at lower uncertainties are available for national laboratories.

‡Depth is measured from the bottom of the thermometer well to the top of the pure reference material.

 

Ordering Information

5900

Mercury Cell, Stainless Steel

5904

Indium Cell, Traditional Quartz Glass

5905

Tin Cell, Traditional Quartz Glass

5906

Zinc Cell, Traditional Quartz Glass

5907

Aluminum Cell, Traditional Quartz Glass

5908

Silver Cell, Traditional Quartz Glass

5909

Copper Cell, Traditional Quartz Glass

5924

Indium Cell, Open Quartz Glass

5925

Tin Cell, Open Quartz Glass

5926

Zinc Cell, Open Quartz Glass

5927A-L

Aluminum Cell, Open Quartz Glass, Long

5927A-S

Aluminum Cell, Open Quartz Glass, Short

5928

Silver Cell, Open Quartz Glass

5929

Copper Cell, Open Quartz Glass

5943

Gallium Cell, Metal Cased

2068-D

Stand, Fixed-Point Cell, Black Delron

Buďte prvý, kto napíše príspevok k tejto položke.