Fluke Calibration 5627A - Probe (–200°C to 420°C)

  • Vibration and shock resistant
  • 3/4-inch bend radius for increased durability
  • NVLAP-accredited calibration included
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 3003560
€1 207,20 €1 006 bez DPH
Fluke Calibration 5627A - Probe (–200°C to 420°C)
Fluke 5627 - sonda –200°C až 420°C
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

When buying a PRT, performance isn’t the only criterion you need to look at. The real issues are price-to-accuracy and price-to-durability ratios. 

The 5627A probes have a temperature range up to 420 °C and an accuracy as good as ±0.05 °C. They come in three different lengths. (The six-inch and nine-inch model covers –200 °C to 300 °C.) Each instrument is shipped with its ITS-90 coefficients and a calibration table in 1 °C increments. 

One of the best features of this sensor is that it conforms to the standard 385 curve, letting you use your DIN/IEC RTD meters fully. Why use a probe that’s less accurate than your meter? 

The 5627A is manufactured using a coil suspension element design for increased shock and vibration resistance. It has a mineral-insulated sheath with a minimum bend radius of 19 mm (3/4-inch) for flexibility and durability. (Bend, if any, should be specified at time of order.) 

Six-inch and nine-inch 5627s are calibrated at –196 °C, –38 °C, 0 °C, 200 °C, and 300 °C. For the 12-inch version, the point at 300°C is replaced with a point at 420 °C. 

Each probe is individually calibrated and includes a NVLAP-accredited report of calibration from the manufacturer.

This probe is an excellent value. It has the price-to-accuracy and price-to-durability ratios you should demand in every  PRT you buy! 

Specifications 

Resistance 

Nominal 100W 

Temperature Coefficient 

0.00385W/W/ °C nominal 

Temperature Range 

–200 °C to 420 °C
(5627-6 and 5627-9 to 300 °C; transition and cable temperature: 0 °C to 150 °C) 

Drift Rate 

±0.13 °C at 0 °C after 1000 hours at 400 °C 

Sheath Material 

316 Stainless Steel 

Leads 

Teflon™-insulated, nickel-plated stranded copper, 22 AWG 

Termination 

Specify. See Ordering Information. 

Time Constant 

Four seconds maximum for 63.2 %Response to step change in water moving at 3 fps. 

Bending Radius 

Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Hart lab requires 20 cm [8 in] of unbent sheath to re-calibrate.) 

Calibration 

Includes a NVLAP-accredited calibration and table with R vs. T values in 1 °C increments from –196 °C to 500 °C (to 300 °C for 5627-6 and 5627-9). ITS-90 coefficients included. Optional accredited calibration available from Hart. 

Immersion 

At least 100 mm (4 in) recommended 

Accuracy (includes calibration uncertainty and short-term stability) 

±0.050 °C at –196 °C
±0.050 °C at 0 °C  
±0.051 °C at 200 °C  
±0.055 °C at 420 °C  

Size 

5627A-12:12 in L x 1/4 in Dia.
5627A-9: 9 in L x 3/16 in Dia.
5627A-6: 6 in L x 3/16 in Dia. 


Ordering Information 

5627A-6-X 

Secondary PRT, 152 mm x 4.7 mm (6 x 3/16 in), –200 °C to 300 °C 

5627A-9-X 

Secondary PRT, 229 mm x 4.7 mm (9 x 3/16 in), –200 °C to 300 °C 

5627A-12-X 

Secondary PRT, 305 mm x 6.35 mm (12 x 1/4 in), –200 °C to 420 °C 

2601 

Probe Carrying Case 

X = termination. Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522 Handheld Thermometers), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), or “S” (spade lugs). 

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: