Fluke Calibration 5618 - Small Diameter Industrial RTD

  • Small diameter sheath, 3.2mm (0.125 in) 
  • Excellent stability 
  • Includes ITS-90 coefficients 
  • NVLAP-accredited calibrated from –200°C to 500°C 
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 3376977
€1 460,40 €1 217 bez DPH
Fluke Calibration 5618 - Small Diameter Industrial RTD
Fluke 5618 - industriálna RTD
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

For secondary level performance with full ITS-90 calibration, Hart’s 5618B series PRTs are an excellent choice for critical temperature measurements. Featuring a 3.2 mm diameter (1/8 in) sheath, these industrial standards probes have reduced response time without compromising precision. This small diameter 5618A probe works well in many applications where immersion depth is limited. Larger diameter probes give more measurement error in short immersion depth applications because they conduct more heat between ambient and the sensor. 

With each probe you will receive a full NVLAP-accredited calibration report. On the report you’ll get the test data and the ITS-90 calibration coefficients that you can easily input into your Hart thermometer. If you are using a 1521 Handheld Thermometer readout, we’ll program the coefficients directly into your INFO-CON connector. 

The 5618B is also a great probe to use for calibrating your Hart 9132 or 9133 infrared calibrators. In fact, these IR black body heat sources were designed to be calibrated with this type of probe. Now you can calibrate these targets in your own lab! 

For use from –200 °C to 500 °C (the six-inch model goes to 300 °C), you won’t find a better industrial standard in this configuration than our 5618B. We recommend using the 5618B PRTs with the 1521, 1522, 1502A, 1529, or 1560 thermometer readouts. 

Specifications 

Resistance 

Nominal 100W at 0 °C 

Temperature Coefficient 

0.003923W/W/ °C nominal 

Temperature Range 

–200 °C to 500 °C
(–200 °C to 300 °C for 5618A-6-X) 

Drift Rate 

±0.1 °C when used periodically to 500 °C 

Sheath Material 

316 SST 

Leads 

22 AWG Teflon, 6’ 

Termination 

Specify 

Hysteresis 

Less than 0.01 °C at 0 °C when using –196 °C and 420 °C as the end points. 

Time Constant 

9 seconds max for 63.2 % 

Thermal EMF 

Less than 25 mV at 420 °C 

Calibration 

Includes NVLAP-accredited calibration w/ITS-90 coefficients, R vs. T values in 1 °C increments 

Size 

5618B-12: 305 mm L x 3.2 mm dia. (12 x 1/8 in)
5618B-9: 229 mm L x 3.2 mm dia. (9 x 1/8 in)
5618B-6: 152 mm L x 3.2 mm dia. (6 x 1/8 in) 

Probe Accuracy  (includes calibration uncertainty and short-term stability) 

±0.05 °C over entire range 


Ordering Information 

5618B-12-X 

305 mm (12 in) Small Diameter Probe 

5618B-9-X 

229 mm (9 in) Small Diameter Probe 

5618B-6-X 

152 mm (6 in) Small Diameter Probe 

2601 

Probe Carrying Case 

X = termination. Specify “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522 Handheld Thermometers), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), or “S” (spade lugs). 