Fluke Calibration 3102 - vložka pre Fluke 9102 a 9009

  • Temperatures from –15 °C to 350 °C in one unit
  • Two wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water-resistant enclosure
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1650985
€201,60 €168 bez DPH
Fluke Calibration 3102 - vložka pre Fluke 9102 a 9009
Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky;Fluke 3102 - vložka do piecky
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

You’ve been asking for it and now we’re making it for you.  Hart’s new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time.  Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.

The Model 9009 includes two independently controlled temperature blocks.  The hot block provides temperatures from 50°C to 350°C, while the cold block covers the range –15°C to 110°C.  Each block is controlled by a precision Hart Scientific temperature controller.  These aren’t some off-the-shelf controllers we glued into a box.  These are Hart Scientific controllers from the leading temperature company in the world.

Each temperature block includes two wells with removable inserts.  You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero” and “span” references for transmitter calibrations.

Need portability and durability?  The 9009 is housed in a tough Pelican™ case that is both airtight and watertight.  It’s a small package weighing only 10 pounds, yet it fits everything you need, including a power cord and four extra inserts. Inserts are available to accommodate sensors of any size from 1/16" (1.6 mm) to 7/16” (11.1 mm).  This rugged system can go anywhere.

Of course the 9009 also delivers the performance you expect from a Hart Scientific temperature source. The cold block is calibrated to within ±0.2°C with stability of ±0.05°C.  The hot block’s display is accurate to ±0.6°C with stability of ±0.05°C. A NIST-traceable calibration is included for each of the two test blocks.

For use with automated systems, the 9009 comes with an RS-232 connection and our Model 9930 Interface-it software, which allows you to control and monitor temperatures from your PC.  For completely automated calibrations, Hart’s MET/TEMP II software also integrates with the 9009.

Two blocks in one unit, a total range of –15°C to 350°C, portability, durability, versatility, performance, automation. Hart Scientific delivers it all.

Specifications 

Hot Block  Cold Block 

Range 

50 °C to 350 °C (122 °F to 662 °F) 

–15 °C to 110 °C (5 °F to 230 °F) 
(–8 °C [18 °F] with hot block at 350 °C [662 °F]) 

Accuracy 

±0.6 °C 

±0.2 °C 

Stability 

±0.05 °C 

Well-to-Well Uniformity 

±0.1 °C 

Display Resolution 

0.1 ° 

Heating Times 

10 minutes from 25 °C to 350 °C 

15 minutes from 25 °C to 110 °C 

Cooling Times 

30 minutes from 350 °C to 100 °C 

16 minutes from 25 °C to –15 °C 

Stabilization Times 

8 minutes 

Well Depth 

4" (102 mm) 

Removable Inserts 

Two 6.4 mm (1/4 in) and two 4.8 mm (3/16 in) inserts included; see Ordering Information for other available inserts 

Computer Interface 

RS-232 included with free Interface-it software 

Power 

115 VAC (±10 %), 3 A, or  230 VAC (±10 %), 2 A, specify, 50/60 Hz, 280 W 

Size (HxWxD) 

178 x 267 x 248 mm (7 x 10.5 x 9.75 in) 

Weight 

4.5 kg (10 lb.) 

NIST-Traceable Calibration 

Data at 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, and 350 °C 

Data at –8 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 110 °C 


Ordering Information 

9009-X 

Industrial Dual-Block Dry-Well (X = case color. Specify “B” for black or “Y” for yellow.)  Includes two 1/4 in (6.4 mm) and two 3/16 in (4.8 mm) inserts. 

3102-0 

Insert, Blank 

3102-1 

Insert, 1/16 in (1.6 mm) 

3102-2 

Insert, 1/8 in (3.2 mm) 

3102-3 

Insert, 3/16 in (4.8 mm) 

3102-4 

Insert, 1/4 in (6.4 mm) 

3102-5 

Insert, 5/16 in (7.9 mm) 

3102-6 

Insert, 3/8 in (9.5 mm) 

3102-7 

Insert, 7/16 in (11.1 mm) 

3102-8 

Insert, 5/32 in (4 mm) 

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: