Fluke Calibration 2100-T - Controller, Thermistor

  • Most stable temperature controllers available
  • Resolution as high as 0.00018°C
  • RS-232 interface included for automating applications
Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 2430381
€120 €100 bez DPH
Fluke Calibration 2100-T - Controller, Thermistor
Fluke 2100-T - termistorový ovládač
Cena na požiadanie
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

It’s no secret why Hart’s temperature baths are the most stable baths in the world. In fact, right on page 96 of this catalog we explain that Hart baths use Hart temperature controllers, and they’re flat out the best anywhere. 

If you’re using a homemade bath—or worse, a bath built by one of our competitors—there’s a good chance you can drastically improve its performance by using one of Hart’s two temperature controllers. 

The 2100 controller can sense and respond to temperature changes as low as 0.00001 °C, which means you can enjoy stabilities better than ±0.001 °C in a mechanically sound bath. 

The 2100 has set-point resolution of 0.002 °C using a thermistor input and 0.01 °C using an RTD input. In high-resolution mode you can adjust the set-point in increments smaller than 0.0002 °C. Actual display resolution is 0.01 °C. 

Power output is provided on a standard IEC female power receptacle. An auxiliary power output provides constant line voltage to equipment accessories such as stirrers. 

The 2200 controller is smaller and lighter than the 2100 and uses an RTD input to provide stabilities as good as ±0.015 °C. Resolution is 0.01 °C and temperature range is –100 °C to 800 °C. 

If operated from any line power between 100 and 230 VAC, 50 or 60 Hz, the 2200 will supply up to 10 amps power output on a standard IEC female power receptacle. 

Both models are programmed using the front-panel buttons and also come with an RS-232 interface. 

Either of these benchtop controllers can turn an average temperature bath into a true calibration tool. Call us and tell us your application. We’ll help you pick the best controller for your situation. 

Specifications

Temperature Range

2100: –100 °C to 670 °C
2200:
–100 °C to 800 °C

Control Stability

2100: ±0.0005 °C to ±0.002 °C
2200:
±0.005 °C to ±0.02 °C
(depends on system design)

Display Accuracy (with probes shown below)

±1.0 °C without system calibration

Display Resolution

0.01 °

Set-Point Resolution

2100: 0.0002 ° in high-resolution mode
2200: 0.01 °

Auxiliary and Heater Output

2100: 100–125 nominal VAC or 230 nominal VAC (internally switchable), 50/60 Hz, 10 A max.

2200: 100–230 VAC, 50/60 Hz, 10 A max.

Heater Output

Solid-state relay

Dimensions (HxWxD)

2100: 72 x 172 x 250 mm (2.83 x 6.75 x 9.86 in)
2200:
72 x 114 x 178 mm (2.85 x 4.5 x 7 in)

Probes

2620: RTD, 280 x 4.8 mm (11 x 0.187 in), –100 to 550 °C
2622:
RTD, 229 x 4.8 mm (9 x 0.187 in), –100 to 550 °C
2624:
RTD, 356 x 4.8 mm (14 x 0.187 in), –100 to 550 °C
2611:
Thermistor, 229 x 5.5 mm (9 x 0.218 in), –10 °C to 110 °C (2100 controller only)
5635:
Type K thermocouple, 406 x 4.7 mm (16 x 0.187 in), 1100 °C for cutout

Automation Software

Both models include Hart’s 9930 Interface-it software package (see page 80)

Ordering Information

2100-P

Controller, PRT

2100-T

Controller, Thermistor

2200

Controller, PRT

2125

IEEE-488 Interface

2611

Thermistor Probe

5635-S

Thermocouple Cutout Probe

2620

RTD Probe, 11 in

2622

RTD Probe, 9 in

2624

RTD Probe, 14 in