Fluke Bm. BP Pump 2M - Overovanie a testovanie vlastností tlakomerov

Značka: Fluke Biomedical

The BP Pump 2 provides dynamic blood-pressure simulations for testing NIBPM"s (Non-Invasive Blood Pressure Monitors), including arm- and wrist-cuff types. In addition, the BP Pump 2 can test for leaks, measure static pressure, generate pressure, and test overpressure valve. The BP Pump 2 also uses optional synchronized ECG simulation for testing NIBPM, utilizing gated measurement for noise/artifact rejection. A high-accuracy pressure-transducer model is also available to fulfill EN1060-3 requirements. (See “Models.”)

Dostupnosť Opýtajte sa
Možnosti doručenia
Kód: 1339
€1 €0,83 bez DPH
Fluke Bm. BP Pump 2M - Overovanie a testovanie vlastností tlakomerov
Značka: Fluke Biomedical
Fluke Bm. BP Pump 2M  - Overovanie a testovanie vlastností tlakomerov
Ukončená výroba
Doprava zadarmo pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Doprava zadarmo
pre každý nákup nad 80€ s DPH vytvorený cez náš eshop s doručením na Slovensko.
Široké možnosti platby na dobierku, kartou online alebo bankovým prevodom.
Široké možnosti
platby a doručenia pre vaše pohodlie. Prijímame platobné karty, Google Pay alebo Apple Pay.
Tovar skladom odosielame v deň objednávky (do 13:00)
Tovar skladom
odosielame v deň objednávky kuriérom SPS alebo službou Packeta (objednávky do 13:00).
Záručný, pozáručný servis teplomerov, multimetrov a iného metrologického vybavenia.
Servis a kalibrácia
teplomerov, multimetrov a iného metrologického vybavenia vrátane záručného a pozáručného servisu.

Standard Features

  • Dynamic NIBPM simulations for arm- and wrist-cuff monitors
  • Internal pump for use in high- and low-pressure release verification, leak testing and pressure sourcing
  • Preset mode (for simulation of most patient conditions) or user-defined simulations
  • Internal adult/neonatal cuffs for testing NIBPM separately from cuff
  • Respiratory artifacts including spontaneous breathing and controlled ventilation
  • Arrhythmia simulations including premature atrial contractions #1 and #2, atrial fibrillation and PVCs

Optional Features

    • High-accuracy pressure transducer
    • Synchronization of ECG and arrhythmia simulation with BP

BP pump 2, BPPUMP, bppump2

Specifications
Display
  Bright, large 4-line x 40 character alphanumeric display with backlighting
Pressure Generation/Measurement
Static-pressure range 0 mmHg to 400 mmHg(53 kPa)
Difference Between Target Pressure and Actual Pressure: -5 mmHg
Internal Leak Rate: < 2 mmHg per minute with minimum volume of 300 cc
Four Respiratory Artifacts
  3 spontaneous breathing
  controlled ventilation
3 Adult Wrist-Cuff Simulations
  Normal
  Hyper
  Hypo
Pressure Source
  Specified pressure generated from 0 mmHg to 400 mmHg in selectable increments of 1 mmHg
Pressure Gauge
  Static pressure measured from 0 mmHg to 400 mmHg at the pressure port
Pressure Relief Rest
  Test for the NIBPM pressure relief valve (0 mmHg to 400 mmHg) with display of peak pressure
Neonate Internal Cuff Simulations
  Internal neonate cuff
  Four standard neonate pressures
Normal Sinus Rhythm
BP and ECG - Healthy heart
  - Weak pulse
  - Mild exercise
  - Strenuous exercise
  - Obese subject
  - Geriatric subject
  - Tachycardia
  - Bradycardia
Irregular Pulse
BP and ECG - Premature atrial contractions # 1
  - Premature atrial contractions # 2
  - Premature ventricular contractions
  - Atrial fibrillation and PVCs
User-Definable Simulations
  User-defnable systolic and diastolic values, along with heart rate and pulse volume
Ranges:  
- Systolic Pressure Range: 20 to 250
- Diastolic Pressure Range: 10 to 200
- Heart Rate: 30 to 250
- Pulse Volume: 0.1 cc to 2.4 cc
Simulation Parameters Performance
Max Pulse Volume: 2.4 cc
Max Heart Rate: - 200 BPM at 2.4 cc pulse volume
  - 250 BPM at 1.2 cc pulse volume
Internal Neonatal Cuff Volume: 20 cc
Internal Adult Cuff Volume (Including NN Volume): 310 cc
Heart Rate Setting Accuracy: ± 1 BPM
Simulation Units: kPa and mmHg (user selectable)
Pressure Leak Test
  The pressure port is pressurized from 0 mmHg to 400 mmHg and keeps track of the pressure loss over time. Peak pressure and present pressure are displayed at all times; leak rate is displayed when it is available.
Autosequences
  Nine autosequences are provided for four tests and up to five simulations.
Electrical ECG
Signals: RA, LA, RL, LL, V
Waveform: Lead II
Amplitude: 1 mV peak (± 10 %)
Connections: Optional external ECG adapter
  Physiological synchronization with NIBP
Serial Port
  Bidirectional RS232 port; baud rate of 9600 with no parity, one stop bit, and eight data bits.
Pressure Measurement
Pressure-Measurement Units: kPa, mmHg, cmH 2 0, cmH 2 O and psi (user selectable)
Pressure-Measurement Range: 0 mmHg to 400 mmHg
Pressure-Measurement Resolution: 0.1 kPa, 1.0 mmHg, 1.0 cmH 2 O, and 0.1 psi
Pressure-Measurement Accuracy:  
- Standard Version (BP Pump 2 L ): - 0 to 300 mmHg: + 0.5 % of reading + 1 mmHg
  - 301 to 400 mmHg: + 2 % of reading
- High-Accuracy Version (BP Pump 2 M ): - < 0.8 mmHg (0.1 kPa) throughout range
Parallel Port
  25-pin female connector, with D-subminiature style and pinouts conforming to IBM "PC" printer port (unidirectional), HP and ASCII printers.
Sample Adult Arm-Cuff Simulation Parameters (Standard)
Standard Set of Blood Pressures  
- BP #1 Blood Pressure : 120/80 (93)
  Heart Rate : 80
  Pulse Volume : 0.68 cc
- BP #2 Blood Pressure : 150/100 (116)
  Heart Rate : 80
  Pulse Volume : 0.65 cc
- BP #3 Blood Pressure : 200/150 (166)
  Heart Rate : 80
  Pulse Volume : 0.60 cc
- BP #4 Blood Pressure : 255/195 (215)
  Heart Rate : 80
  Pulse Volume : 0.55 cc
- BP #5 Blood Pressure : 60/30 (40)
  Heart Rate : 80
  Pulse Volume : 0.75 cc
- BP #6 Blood Pressure : 80/50 (60)
  Heart Rate : 80
  Pulse Volume : 0.70 cc
- BP #7 Blood Pressure : 100/65 (76)
  Heart Rate : 80
  Pulse Volume : 0.69 cc
Dimensions
  10 in L x 10 in D x 5 in H
  (25.4 cm L x 25.4 cm D x 12.7 cm H)
Weight
  7.5 lb
  (3.4 kg)

Buďte prvý, kto napíše príspevok k tejto položke.

Nevypĺňajte toto pole: